BPMNM - RP55, CALCOMP REPLENISHER

  • MSDS: BPMNM
  • Manufacturer: CALCOMP INC
  • Product Name: RP55, CALCOMP REPLENISHER
  • National Stock Number: 6750-01-350-5095
Product Identification

Product ID:RP55, CALCOMP REPLENISHER
MSDS Date:03/26/1991
FSC:6750
NIIN:01-350-5095
MSDS Number: BPMNM

Responsible Party
CALCOMP INC
2411 W LA PALMA AVE
ANAHEIM, CA 92801
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 714-821-2114

Preparer: CRAIG SUNDQUIST

Cage: 14656

Contractor
CALIFORNIA COMPUTER PRODUCTS SUB OF SANDERS ASSOC
3250 ANAHEIM, CA 92803 US

Telephone: 714-821-2730

Cage: 14668

Ingredients

HYDROTREATED HEAVY NAPHTHA;(ALIPHATIC HYDROCARBON (ISOPAR

CAS: 64742-48-9

Fraction By Weight: >80%


METHACRYLATE COPOLYMER

Fraction By Weight: <10%


CARBON BLACK

CAS: 1333-86-4

RTECS: FF5800000

Fraction By Weight: <10%

OSHA PEL 3.5 MG/M3

ACGIH TLV: 3.5 MG/M3


CNTRL AGENCY FOR ASSISTANCE. POSS DISP METH INCL

RTECS: 9999999ZZ


RECYCLED MATLS SHOULD NOT BE USED WITH CALCOMP

RTECS: 9999999ZZ


OF HEATING, AIR CONDITIONING, & REFRIGERATING

RTECS: 9999999ZZ


OF USE. UNDER SOME CNDTNS OF USE OR COMBINATIONS OF

RTECS: 9999999ZZ


THAT VENT IS SUFFICIENT TO PVNT EXCEEDING EXPOS

RTECS: 9999999ZZ


INDUSTRIAL HYGIENIST IF A CONCERN REGARDING EXPOSURE

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN:CAN CAUSE DRYING OR IRRIT.
EYE:MAY CAUSE IRRIT. INHAL:MAY CAUSE HDCH & DIZZ. INGEST:PROD HAS
LOW ORDER OF ACUTE ORAL TOX BUT IF ASPIR INTO LUNGS DURING INGEST
OR VOMIT, MAY CAUSE MILD TO SEVERE P ULM INJURY & POSS DEATH.
SIGNS/SYMPS:HIGH VAP CONC (>1000 PPM) ARE IRRIT TO EYES/RESP TRACT,
MAY CAUSE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:HEADACHES & DIZZINESS, ARE ANESTHETIC,
& MAY HAVE OTHER CNS EFTS. DEATH POSSIBLE IF EXPOSED TO VERY HIGH
CONCENTRATIONS FOR PROLONGED PERIODS. PERSONS SENSITIVE TO
HYDROCARBON EXPOS MAY EXPER IENCE DISCOMFORT WHEN EXPOSED TO
CONCENTRATIONS BELOW ESTABLISHED SAFE EXPOSURE LIMIT.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYE:FLUSH W/CLEAR WATER FOR AT LEAST 15 MINS OR UNTIL IRRIT
SUBSIDES. IF IRRIT PERSISTS, CALL MD. SKIN:REMOVE CONTAM CLTHG.
WASH SKIN THORO W/SOAP & WATER. DO NOT REUSE CONTAM CLTHG UNTIL
SOLVS HAVE B EEN REMOVED. INHAL:MOVE TO FRESH AIR. CALL MD IMMED.
IF BRTHG IRREGULAR/STOPPED, START RESUSCITATION IF TRAINED. GIVE
O*2 IF AVAIL INGEST:DILUTE STOMACH CONTENTS W/SEVERAL GLASSES OF
WATER. DO(SUPDAT)

Fire Fighting

Flash Point Method:TCC
Flash Point:104F,40C
Lower Limits:0.7%
Upper Limits:7%
Extinguishing Media:FOAM, DRY CHEMICAL, OR CARBON DIOXIDE. USE WATER
SPRAY (FOG) TO COOL FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL PROT
EQUIP . NORMAL PROCEDURE FOR COMBUST LIQUIDS. AVOID EXTING W/WATER;
IT TENDS TO SPREAD HYDROCARBON SOLV FIRES.
Unusual Fire/Explosion Hazard:KEEP PROD AWAY FROM SOURCES OF IGNIT SUCH
AS HEAT, SPARKS, PILOT LIGHTS, STATIC ELEC, ELEC APPLIANCES AND
OPEN FLAMES.

Accidental Release

Spill Release Procedures:ELIM ALL IGNIT SOURCES. RECOVER FREE PROD BY
ADDING SAND, EARTH OR OTHER SUITALBE ABSORB TO SPILLED LIQ. KEEP
NON-ESSENTIAL PERS AWAY. AVOID BRTHG VAPS. VENT CONFINED SPACES.
CLEAN-UP ABSORB MATL & DI SP OF PROPERLY. CONTINUE TO OBSERVE PRECS
(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CONTAINERS CLOSED WHEN NOT IN
USE. DO NOT SMOKE WHEN USING PRODUCT. MINIMIZE BREATHING VAPOR OR
MIST. USE WITH ADEQUATE VENTILATION.
Other Precautions:"EMPTY" CONTAINERS RETAIN RESIDUE (LIQUID AND/OR
VAPOR) AND CAN BE DANGEROUS. AVOID PROLONGED OR REPEATED SKIN
CONTACT.

Exposure Controls

Respiratory Protection:NOT NEEDED WHEN USED AS INTENDED WITH CALCOMP
PRODS. IN CONCENTRATIONS EXCEEDING RECOMMENDED SAFE EXPSOURE LIMIT,
SUCH AS DURING A MAJOR SPILL, USE A NIOSH/MSHA APPROVED CHEMICAL
CARTRIDGE RESPIRATOR FOR EFFECTIVE FOR ORGANIC VAPORS.
Ventilation:NO SPEICAL VENT NEEDED WHEN USED AS INTENDED W/CALCOMP
PRODS. NORMAL OFFICE VENT CONFORMING TO AMERICAN SOCIETY (ING 6)
Protective Gloves:NITRILE OR NEOPRENE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:CHEMICAL RESISTANT APRON WHEN CLEANING
MACHINES AS REPLENISHERS MAY STAIN CLOTHING.
Work Hygienic Practices:USE GOOD PERSONAL HYGIENE PRACTICES SUCH AS
WASHING OF HANDS AFTER DONE.
Supplemental Safety and Health
PH:ESSENTIALLY NEUTRAL. % VOLAT:84 @ 1 ATM & 25C (77F). FIRST AID
PROC:NOT INDUCE VOMIT. CALL MD IMMEDIATELY. SPILL PROC:FOR
VOLATILE, COMBUSTIBLE VAPS FROM ABSORBED MATL. THERE IS NOT
REPORTABLE QTY (RQ) UNDER CERCLA REPORTING REQS. WASTE DISP
METH:BASED OILS. CNTCT LICENSED HAZ WASTE DISP COMPANY OR ENVIRON
(ING 4)

Chemical Properties

Boiling Pt:B.P. Text:>311F,>155C
Vapor Pres:<10 @ 25C
Vapor Density:5
Spec Gravity:0.76-.8(H*2O=1)
pH:SUPDAT
Evaporation Rate & Reference:0.3 (BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE (0.1%)
Appearance and Odor:BLACK LIQUID WITH FAINT PETROLEUM HYDORCARBON ODOR
Percent Volatiles by Volume:SUPDAT

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS LIKE LIQUID CHLORINE, CONCENTRATED OXYGEN, AND SODIUM
HYPOCHLORITE OR CALCIUM HYPOCHLORITE.
Stability Condition to Avoid:SOURCES OF IGNITION.
Hazardous Decomposition Products:SMOKE, CO, ALDEHYDES, & OTHER
DECOMPOSITION PRODUCTS WHICH MAY OCCUR IN THE EVENT OF INCOMPLETE
COMBUSTION.

Disposal

Waste Disposal Methods:RCRA HAZ WASTE NO-DOO1. WASTE TONERS &
REPLENISHERS ARE HAZ WASTES AS DEFINED BY 40CFR. ASSURE CONFORMITY
W/ALL APPLIC FED, STATE & LOC DISP REGS. WASTE TONERS &
REPLENISHERS ARE COMPATIBLE FOR DISP W /MOST NON-HALOGENATED SOLVS
& PETROLEUM(SUPDAT)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.